There are a few limitations/restrictions in expressing the effect of performance domestically and internationally.
However, I have no doubt that the consumer will be able to make their own judgement call as long as we clearly outline the treatment method. RF has been a long standing and reliable source of technology.

  • Cartridge used for purpose
    • Pia Quattro - V (Spot 38x51mm) / Pia Cello - M
    • Pia Quattro - V (Spot 38x51mm) / Pia Cello - M
    • Pia Quattro - E / Pia Cello M/S
    • Pia Quattro - V (Spot 53x68mm) / Pia Cello - M
    • Pia Quattro - V (Spot 53x68mm) / Pia Cello - M
  • Pia Quattro-V

  • Pia Quattro-E

  • Pia Cello-M

  • Pia Cello-S

QUATTRO 3D skin treatment

There are skin areas that should be applied gentle suction power and strong suction power according to the skin place. Another factor can minimize bruises by controlling pressure. The pressure adjustment unit is 10mbar.

PIAMO's vacuum RF principle is not conducted in a standard vertical descending method, but is done with a left and right side pulse energy irradiation method. It is a technology that forms a three-dimensional shape with vacuum suction, and then irradiates RF pulses by QRR method through electrodes. One of the most important elements in RF treatment is the temperature control device.

PIAMO maintains a controlled temperature - this is unique design within it’s algorithm. The controlled temperature completes the procedure without overheating the skin - conducted with our special mechanical, hardware, and program control technology.

There are skin areas that should be applied gentle suction power and strong suction power according to the skin place. Another factor can minimize bruises by controlling pressure. The pressure adjustment unit is 10mbar.

The Pia Quattro is built for the user to select 4 electrodes or 2 electrodes, depending on how
they intend to use the cartridge. All cartridges and disinfected and ready for use.

The handpiece tip is detachable, and one can maximize results of the treatment
by using the variety of sizes depending on the area being treated.
The Pia Quattro Vacuum Handpiece has a comfortable design that
allows the angle to be adjusted.

After the skin has been vacuumed/treated into a square shape (+)(-), (-)(+)=> XYZ to the hidden space, the QRR method spreads heat evenly and safely. It is a key factor within our technology that effectively delivers RF pulse energy to the area of treatment. The Dynamic Pressure Drive Vacuum System ensures an even and effective distribution of radio frequency energy delivered to the treatment area.

  • Offers a variety of spots

    A variety of spot size options are available based on the skin treatment best suited for each individual. We want to ensure we are providing the best and customizable service for all.

  • Cleaning and disinfection

    Quattro electrode cartridges can be separated, washed, and disinfected after each use. This optimizes that each process is clean and safe.

  • Pia Quattro-V

    53 X 68 mm

  • Pia Quattro-V

    53 X 68 mm

  • Pia Quattro-V

    38 X 51 mm

  • Pia Quattro-V

    38 X 51 mm

  • Pia Quattro-V

    36 X 40 mm

  • Pia Quattro-V

    36 X 40 mm

  • Pia Quattro-E

    20 X 23 mm

  • Offers a variety of spots

    There are various spot sizes to fit your skin Choice allows you to provide better service.

    • Quattro-V

      53 X 68 mm

    • Quattro-V

      53 X 68 mm

    • Quattro-V

      38 X 51 mm

    • Quattro-V

      38 X 51 mm

    • Quattro-V

      36 X 40 mm

    • Quattro-V

      36 X 40 mm

    • Quattro-V

      20 X 23 mm

  • Cleaning and disinfection

    Quattro electrode cartridges can be separated, cleaned, and disinfected after use It is cleaner and safer for the operator.

History of CEO

Mr. Park Won Hee is the Chief Executive Officer (CEO) for PIAMOLIFTING Co.,Ltd. Mr. Park Won Hee is an industry veteran with more than 35 years’ experience in the research, development and production of medical devices.

  • 2022.05

    Establishment of PIAMOLIFTING Co.,Ltd.

  • 2022.04

    Resignation of CEO of NSON Corporation

  • 2015.08

    Establishment of NSON Corporation

  • 2012.03 - 2015.03

    10th President of Chamber of Commerce in Gyeongsangbuk-do Gyeongsan Office

Awards and
Achievements

  • October
    1999

    Presidential Award for Venture Business
    (No. 123274)

  • November 2001

    Prime Minister's Commendation
    (No. 111311)

  • November 2005

    Dongtap Order of Merit Industrial Packaging
    (No. 1811)

Specification

*This specification is subject to change without notice.

  • Frequency

    1MHz

  • Pressure control range

    Min. 150mbar / Max. 650mbar

  • Output power

    Max. 50W

  • Set temperature

    Temperature control selection: Up to 43°C (room temperature 25 °C)

  • Quattro handpiece 4 electrode spot size

    53X68mm / 38X51mm / 36X40mm

  • Quattro handpiece 2 electrode spot size

    20X23mm / 53X68mm / 38X51mm / 36X40mm

  • Quattro handpiece basic spot

    4 electrode - 38X51mm (2ea) / 2 electrode - 20X23mm(E) (2ea)

  • Cello handpiece M size

    25X25mm

  • Cello handpiece S size

    17X19mm

  • Operating voltage

    200VAC / 60Hz

  • Device weight

    approx, 25kg

  • Device size

    approx. 392.5 X 436.5 X 1059.6mm

  • Energy survey method

    two way grid method/ XYZ method / XZ method

  • Detachable vacuum handpiece electrode part
    Handpiece angle adjustable
    Vacuum handpiece OLED LCD temperature display

  • options

    Quattro handpiece spot
    4 electrode - 53X68mm / 36X40mm
    2 electrode - 53X68mm / 38X51mm / 36X40mm
    Cello L : 41X41mm

Thank you for
visiting PIAMO

If you inquire about the product you are curious about,
we will answer it kindly and quickly.

  • Item namea general-purpose electrosurgical instrument
  • Purpose of Usean instrument that uses high-frequency current to coagulate tissue

* This product is a 'medical device', and please read and use the 'Precautions for use'
and 'How to use' carefully.

Name

Company

Contact

E-mail

Type of inquiry type

Personal information processing policy

View full text